| Standards |
Subject |
Result |
| UBC 26-9 / NFPA 285 |
ISMA Test - Intermediate-Scale Multistory Apparatus |
Passed |
| ASTM E 119 |
Fire Test of Building Construction and Materials |
One and two hour rated wall assembly successfully passed |
| ASTM E 84 |
Surface Burning Characteristics of Building Materials |
Flame Spread Index : 0 Smoke Developed Index: ≤ 5 |
| UPITT TOXICITY TEST |
Investigation of the Toxic Potency of Combustion Products |
Passed |
| UBC 26-3 |
Form Plastic System |
Passed |
| ASTM E 162 |
Surface Flammability of Materials Using a Radiant Heat Energy Source |
Flame Spread Index Average : 0 Range : 0 to 0 |
| ASTM E 648 / NFPA 253 |
Critical Radiant Flux of Floor-Covering Systems Using a Radiant Heat Energy Source |
No Ignition
No Smoke |
| ASTM D 1929 |
Determining Ignition Temperature of Plastics |
Spontaneous ignition Temperature STI : 450°C (842°F)
Flash Ignition Temperature FTI : 440°C (824°F) |
| ASTM D 635 |
Time of Burning of Self-Supporting Plastics in a Horizontal Position |
No Average Time Burning (ATB)
No Average Extent of Burning (AEB) |
| ASTM E 662 |
Specific Optical Density of Smoke Generated by Solid Materials |
Flaming : 18.20
Non-flaming : 0.69FTI : 440℃ (824º F) |
| ASTM D 2015 |
Gross Calorific Value of Coal and Coke by the Adiabatic Bomb Calorimeter |
4,080 BTU/lb |
* ASTM: American Society for Testing and Materials
|