ALCOTEX FR| Test Results
United States FR Test Results
Standards Subject Result
UBC 26-9 / NFPA 285 ISMA Test - Intermediate-Scale Multistory Apparatus Passed
ASTM E 119 Fire Test of Building Construction and Materials One and two hour rated wall assembly successfully passed
ASTM E 84 Surface Burning Characteristics of Building Materials Flame Spread Index : 0 Smoke Developed Index: ≤ 5
UPITT TOXICITY TEST Investigation of the Toxic Potency of Combustion Products Passed
UBC 26-3 Form Plastic System Passed
ASTM E 162 Surface Flammability of Materials Using a Radiant Heat Energy Source Flame Spread Index Average : 0 Range : 0 to 0
ASTM E 648 / NFPA 253 Critical Radiant Flux of Floor-Covering Systems Using a Radiant Heat Energy Source No Ignition
No Smoke
ASTM D 1929 Determining Ignition Temperature of Plastics Spontaneous ignition Temperature STI : 450°C (842°F)
Flash Ignition Temperature FTI : 440°C (824°F)
ASTM D 635 Time of Burning of Self-Supporting Plastics in a Horizontal Position No Average Time Burning (ATB)
No Average Extent of Burning (AEB)
ASTM E 662 Specific Optical Density of Smoke Generated by Solid Materials Flaming : 18.20
Non-flaming : 0.69FTI : 440℃ (824º F)
ASTM D 2015 Gross Calorific Value of Coal and Coke by the Adiabatic Bomb Calorimeter 4,080 BTU/lb

* ASTM: American Society for Testing and Materials

Canadian FR Test Results
Standards Subject Result
 CAN/ULC S134-92 Fire Test of Exterior Wall Assemblies Passed
 CAN/ULC S102-07 Surface Burning Characteristics Flame Spread 0
Smoke Developed 0
 